The Long Road to a New Standard


Reading time ( words)

Graham Naisbitt, chairman and CEO of Gen3 Systems, has spent decades leading cleanliness testing standards in a number of different standards organizations like IPC, IEC, and ISO around an assortment of testing methods, such as CAF, SIR, and even introducing a new standard this year for his own testing method—process ionic contamination testing (PICT). Naisbitt breaks down his long involvement with standards and where they stand currently.

Barry Matties: Please start by telling us about your company, Gen3 Systems.

Graham Naisbitt: For nearly 40 years, we have designed, engineered, manufactured, and distributed our test and measurement equipment into the electronics industry. Back in 2009–2010, we lost 50% revenue overnight in the downturn. It was as though somebody flicked a switch. To bolster what we’re doing in the U.K., looking for distribution of other people’s products was a natural extension, so we lined up with two or three key players. Peter Marshall, who was the chairman of the SMART Group (a trade association in the U.K.), was at a crossroads. He had his own distribution business and wanted to retire. Peter and I came to an agreement, and I took over that business, which brought in additional distribution points.

Matties: As you told me earlier, there was one event that changed the course of your work.

Naisbitt: An important point for the industry was when Dr. Wally Rubin, who was then the technical director of a company called Multicore Solders, invented no-clean flux. Wow, that was a success. But how much longer that can continue has now come into question.

Matties: Are there some practical applications that need to be addressed?

Naisbitt: Absolutely. And it’s fair to say that the vast majority of the industry is running successful no-clean processes, but it doesn’t avoid the risks associated with electrochemi cal migration notably, which takes so many different forms.

Matties: And with HDI coming into a stronger play in the market, are we seeing more failures?

Naisbitt: Yes. That was why we became involved with the conformal coating because it helped to protect the circuitry. That was the first introduction I had into what makes electronic circuits reliable. That was the key feature of our business.

I became more involved at that point to figure out how to control the production process. One of the main elements of this is that all fluxes leave residues. Surface insulation resistance (SIR) testing was developed and used to try to evaluate whether it was acceptable or not when you were using a no-clean process. With a new process and test, then you need to develop the standards. In 2007, I finally managed to publish the first meaningful documents, which was the IPC test method, and coincidentally, the IEC standard. From there, we have developed even further. The issue came into play around 2010–2012 as the industry was migrating more into increased packaging density and insulation resistance testing became a necessity if you needed to establish product reliability.

But the question that kept coming back to me is how do you control a process? You can’t use SIR testing because it takes too long and it’s too cumbersome and complex. But what you can do is use that to establish a reliable production process, and then take it from there. You need to be able to measure any mobile ionic species left on the surface that can compromise performance because if you put electricity through a product in a damp environment—and you have ionics present as well as the perfect electrolytic cell—funny stuff happens.

During this time, there was some research into this subject, and a stake was stuck in the ground that said anything above 1.56 micrograms per centimeter squared of sodium chloride equivalent is bad and below is good. Now, unfortunately, the industry started without any hesitation to adopt the term “cleanliness testing,” and it isn’t. It never was.

The challenge is the simplified ion chromatograph test, aka ROSE testing, doesn’t differentiate species; it simply looks at a value of conductivity of the solution as to whether or not it falls within acceptable limits. I have spent 25 years of my life trying to explain this to people. You have to stop thinking of it as a cleanliness test because it isn’t, but it’s an excellent method to control a process.

Around 2013, we received a call from Robert Bosch. They require Six Sigma for their production process. It’s automotive electronics that are ultra-high reliability and safety-critical. We took on the project, and in five years of work, we achieved Six Sigma verification uniquely for the first time in the history of this entire subject. To do this, the instrument needs to be sufficiently capable of detecting changes in the process as fast as possible. We use a merit-to-fit algorithm. It means that we were able to give an accurate go/no-go answer within typically three to five minutes. What we’re looking for are only those mobilizable ionic species. Cleanliness is something entirely different.

Matties: After your five years of work, the current pass-fail approach doesn’t make sense as a standard. What was the response, and how do you carry that change in the standard process to the industry and get support?

Naisbitt: There are two answers to that. One, I’m silly.

Matties: That was a short answer (laughs).

 

To read the full version of this article which originally appeared in the September 2019 issue of SMT007 Magazine, click here.

Share

Print


Suggested Items

CFX Preview at IPC APEX EXPO 2020

01/13/2020 | I-Connect007 Editorial Team
The I-Connect007 Editorial Team chats with IPC’s Chris Jorgensen about the advances CFX has made in the past year and where the standard is in the standardization process. Chris also previews the CFX line that will be on display at the upcoming IPC APEX EXPO and shares IPC’s plans on educating and providing support solutions to potential users of CFX to implement it more easily.

Updates on Cleaning Standards and Committees

01/08/2020 | Nolan Johnson, I-Connect007
Graham Naisbitt of Gen3 discusses the changes he's seeing in cleaning, including how the WP-019 white paper has caused a closer look at electrochemical reliability. As a long-time head of committees, Graham also breaks down many of the topics he hopes are addressed at this year’s IPC APEX EXPO.

IPC Government Relations Team Offering Education and Fun at IPC APEX EXPO

01/07/2020 | Chris Mitchell, IPC Vice President of Global Government Relations
This year’s IPC APEX EXPO is going to be especially interesting for anyone interested in government policies that affect the electronics industry and what IPC is doing to influence them. Your IPC Government Relations team is preparing a variety of activities to educate and engage you on these issues. IPC's Chris Mitchell discusses some of the highlights attendees will see at IPC APEX EXPO from a Government Relations perspective.



Copyright © 2020 I-Connect007. All rights reserved.